Acta Optica Sinica, Volume. 41, Issue 16, 1611003(2021)

Triple-Source Swinging Spiral CT Imaging Method for Security Inspection

Zhenzhen Pi1, Haijun Yu2,3, Lei Li1, Zhongjian Tian1, and Fenglin Liu1,2,3、*
Author Affiliations
  • 1State Key Laboratory of Mechanical Transmission, Chongqing University, Chongqing 400044, China
  • 2Key Laboratory of Optoelectronic Technology and Systems, Ministry of Education, Chongqing University, Chongqing 400044, China
  • 3Engineering Research Center of Industrial Computed Tomography Nondestructive Testing, Ministry of Education, Chongqing University, Chongqing 400044, China
  • show less

    Computed tomography (CT) is one of the important technical means in the field of security inspection. It is of great theoretical and practical value to study new CT imaging methods for security inspection. In this paper, a triple-source swinging spiral CT (TS-SCT) imaging method is proposed, which can be used for the safety inspection of passenger luggage and express parcels. Three groups of X-ray source-detector uniformly distributed in the circumference are used to swing around the rotation center in the range of 120°, the detected object moves along the axial direction in the scanning field of view, and the swing spiral scanning is realized. Compared with spiral CT, the proposed method does not need the whole rotation, and can use the rotating parts which are easier to manufacture, maintain, and are more wear-resistant than the slip-ring. Moreover, the cable is used to transmit data and power, breaking the limitation of a slip-ring on data and power transmission capacity. The imaging model of TS-SCT is established, the effects of scanning mode, scanning parameters, and ratio r between pitch h and projection height T of a cone-beam near the source in z-direction on imaging efficiency and results are analyzed, and the FDK reconstruction algorithm for TS-SCT is derived. The simulated and experimental results show that the TS-SCT FDK reconstruction algorithm is correct and effective, and the TS-SCT method can be used to realize the 3D imaging of detected objects. On the premise of ensuring imaging quality, r≤1/2 is suggested.

    Tools

    Get Citation

    Copy Citation Text

    Zhenzhen Pi, Haijun Yu, Lei Li, Zhongjian Tian, Fenglin Liu. Triple-Source Swinging Spiral CT Imaging Method for Security Inspection[J]. Acta Optica Sinica, 2021, 41(16): 1611003

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Imaging Systems

    Received: Feb. 1, 2021

    Accepted: Mar. 18, 2021

    Published Online: Aug. 12, 2021

    The Author Email: Liu Fenglin (liufl@cqu.edu.cn)

    DOI:10.3788/AOS202141.1611003

    Topics