Acta Optica Sinica, Volume. 34, Issue 12, 1211005(2014)

Calibration and Imaging Model of Light Field Camera with Microlens Array

Zhang Xu1,2、* and Li Chen1
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less

    The light field imaging with microlens array is modeled through analyzing three fundamental factors, such as space, lens, and sensor. The spatial multiplexing is explained and the relationship between the light field and the pixel in raw image is described. Based on the phase shifting, a calibration method is proposed to determine the centers of microlens, the corresponding relationship between the pixel and the microlens, and the character of the microlens vignetting. The experiment is conducted on a commercial light field camera, Lytro. The light field is decoded from the raw image and the refocus image and all-focus image is created from the obtained light field. The experiment results confirm the proposed model and calibration method is valid.

    Tools

    Get Citation

    Copy Citation Text

    Zhang Xu, Li Chen. Calibration and Imaging Model of Light Field Camera with Microlens Array[J]. Acta Optica Sinica, 2014, 34(12): 1211005

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Imaging Systems

    Received: Jun. 10, 2014

    Accepted: --

    Published Online: Nov. 4, 2014

    The Author Email: Xu Zhang (xuzhang@shu.edu.cn)

    DOI:10.3788/aos201434.1211005

    Topics