Acta Optica Sinica, Volume. 32, Issue 2, 222007(2012)

Analysis and Control of Narcissus Effect of Cooling IR Focal Plane System

Liu Yang* and An Xiaoqiang
Author Affiliations
  • [in Chinese]
  • show less

    Cooling IR focal plane system is paraxially analysed with the optical invariant and first order parameters are proposed which quantify the concentrition and variation of narcissus on focal plane arrays (FPA). The ralation between NITD and parameters of environment and system is summarized based on the theory of thermal-radiation theory. The narcissus of an optical design in 3~5 μm with F-number 2.75, view angle 4° and effective focal length 90 mm is caculated and optimised through controlling its first parameters and using real ray trace as confirmation in CODE V, after which the narcissus effect drops by 70%. The distribution of narcissus is simulated on practical conditions in ASAP and the results are presented, it is shown that the NITD dropped down below the preset value after optimization and the narcissus is controlled effectively.

    Tools

    Get Citation

    Copy Citation Text

    Liu Yang, An Xiaoqiang. Analysis and Control of Narcissus Effect of Cooling IR Focal Plane System[J]. Acta Optica Sinica, 2012, 32(2): 222007

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Optical Design and Fabrication

    Received: Jul. 18, 2011

    Accepted: --

    Published Online: Jan. 6, 2012

    The Author Email: Yang Liu (ariter.liu@gmail.com)

    DOI:10.3788/aos201232.0222007

    Topics