Acta Optica Sinica, Volume. 42, Issue 15, 1512002(2022)

Reliability of Mueller Imaging Polarimeter in Pathological Diagnosis

Wen'ai Wang1,2, Ziyu Ma3, Jiabei Li1, Aijun Liu3、**, Yanqiu Li1,2、*, Jiazhi Wang1, Guodong Zhou1, and Yuanhe Li1
Author Affiliations
  • 1Key Laboratory of Photoelectronic Imaging Technology and System, Ministry of Education, School of Optics and Photonics, Beijing Institute of Technology, Beijing 100081, China
  • 2Institute of Engineering Medicine, Beijing Institute of Technology, Beijing 100081, China
  • 3Pathology Department, The 7th Medical Center, Chinese People's Liberation Army General Hospital, Beijing 100700, China
  • show less

    Reliability is an important index to assess the validity of an optical instrument, which is directly related to the practicability of the equipment. Therefore, it is very important to study the reliability of the Mueller imaging polarimeter in pathological diagnosis for its clinical application. In this paper, the Mueller imaging polarimeter which is developed independently by our laboratory is used to diagnose 155 cases of skin tissue sections, including melanoma, pigmented nevus, and normal skin. The depolarization, retardance, and diattenuation can be obtained after the polarimetry. By analyzing receiver operating characteristic (ROC) curves, we find that the diagnostic reliability of depolarization, retardance, and diattenuation of normal and melanoma skin tissue sections is 100%, 100%, and 90%, respectively. The diagnostic reliability of depolarization, retardance, and diattenuation of normal and pigmented nevus skin tissue sections is 99%, 88%, and 75%, respectively. The diagnostic reliability of depolarization, retardance, and diattenuation of pigmented nevus and melanoma is 96%, 97%, and 78%, respectively. The reliability and validity of our homemade Mueller imaging polarimeter have been demonstrated in diagnosing skin sections and the instrument is expected to be a potential tool to assist doctors in pathological diagnosis.

    Tools

    Get Citation

    Copy Citation Text

    Wen'ai Wang, Ziyu Ma, Jiabei Li, Aijun Liu, Yanqiu Li, Jiazhi Wang, Guodong Zhou, Yuanhe Li. Reliability of Mueller Imaging Polarimeter in Pathological Diagnosis[J]. Acta Optica Sinica, 2022, 42(15): 1512002

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Instrumentation, Measurement and Metrology

    Received: Nov. 22, 2021

    Accepted: Mar. 3, 2022

    Published Online: Aug. 4, 2022

    The Author Email: Liu Aijun (aliu@126.com), Li Yanqiu (liyanqiu@bit.edu.cn)

    DOI:10.3788/AOS202242.1512002

    Topics