Bulletin of the Chinese Ceramic Society, Volume. 41, Issue 4, 1285(2022)

Experimental Study on Diagonal-Tension Failure of Steel-Reinforced Basic Magnesium Sulfate Cement Concrete Beams

ZENG Xiangchao1、* and YU Hongfa2
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less

    Basic magnesium sulfate cement concrete (BMSC) has many advantages, such as quick setting, early strength, high tensile strength, resistance to corrosion, and so on. However, the failure of diagonal-tension of BMSC beams has not been studied. In order to explore the differences in mechanical performance between BMSC beams and Portland cement concrete (PC) beams, a comparative test of diagonal-tension failure of the BMSC and PC beams were conducted. The experimental results show that the BMSC beams have advantages in the cracking load and the ultimate bearing capacity compared with the PC beams under diagonal-tension failure. There are some differences in the failure mode between the BMSC and PC beams. The cracking load and the bearing capacity of the BMSC beams are 20% higher than that of the PC beams with the same reinforcement and the same concrete strength grade. So the calculation formulas for cracking load and bearing capacity of the PC beams have been modified. This paper has significance to the application of BMSC in civil engineering.

    Tools

    Get Citation

    Copy Citation Text

    ZENG Xiangchao, YU Hongfa. Experimental Study on Diagonal-Tension Failure of Steel-Reinforced Basic Magnesium Sulfate Cement Concrete Beams[J]. Bulletin of the Chinese Ceramic Society, 2022, 41(4): 1285

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category:

    Received: Nov. 2, 2021

    Accepted: --

    Published Online: Aug. 3, 2022

    The Author Email: Xiangchao ZENG (zxcgzz@sina.com)

    DOI:

    CSTR:32186.14.

    Topics