Acta Optica Sinica, Volume. 29, Issue s1, 368(2009)

Convective Heat Transfer Intensity and Its Enhancing in Plasma Electrodes Pockels′ Cell

Zhang Jun*, Zhang Xiongjun, Wu Dengsheng, Tian Xiaolin, and Wei Xiaofeng
Author Affiliations
  • [in Chinese]
  • show less

    Based on the finite volume modular, the coefficient of convective heat transfer is studied, when plasma electrodes Pockels′ cell is operated at conventional pulse mode. Considering requirement of thermodynamics, the discharge cavity is redesigned to enhance convective heat transfer. The results indicate: at conventional mode, the coefficient of convective heat transfer is too small, 1.01 W/(m2·K), because of low operation pressure, low pumping speed, no considering of thermodynamics requirement. By pushing the pumping speed, increasing operating pressure, augmenting pipe diameter, and redesigning arrangement of inlets and outlets, coefficient of convective heat transfer is enhanced prominently, which reaches to 8.02 W/(m2·K).

    Tools

    Get Citation

    Copy Citation Text

    Zhang Jun, Zhang Xiongjun, Wu Dengsheng, Tian Xiaolin, Wei Xiaofeng. Convective Heat Transfer Intensity and Its Enhancing in Plasma Electrodes Pockels′ Cell[J]. Acta Optica Sinica, 2009, 29(s1): 368

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Optical Devices

    Received: --

    Accepted: --

    Published Online: Jun. 25, 2009

    The Author Email: Jun Zhang (jackie.2010@yahoo.com)

    DOI:

    Topics