Acta Optica Sinica, Volume. 24, Issue 11, 1547(2004)

Optimization of a IR detector of Microcantilever with Carbon Nanometer Tube

[in Chinese]* and [in Chinese]
Author Affiliations
  • [in Chinese]
  • show less

    The theoretical model of the composite microcantilever used in the IR radiation is given based on the theoretical analyses, the infrared absorption characteristics of carbon nanometer tube (CNT) is studied by experiment. A tri-layer microcantilever sensors with CNT film is designed to detect the infrared radiation. The detector is based on the characteristics that the resonance frequency of composite microcantilever shift with the temperature. So, the resonance frequency of microcantilever can be used as sensitive parameter to measure the infrared thermal radiation. The theoretical analysis and simulation results show that this new model can attain power sensitivity of fWtwo orders of magnitude better than the sensitivity of traditional statical ones. Furthermore, the micro-electro-mechanical system (MEMS) sensor could be compatible with integrated circuit technology.

    Tools

    Get Citation

    Copy Citation Text

    [in Chinese], [in Chinese]. Optimization of a IR detector of Microcantilever with Carbon Nanometer Tube[J]. Acta Optica Sinica, 2004, 24(11): 1547

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Received: Dec. 29, 2003

    Accepted: --

    Published Online: Jun. 12, 2006

    The Author Email: (jintail1970@sina.com)

    DOI:

    Topics