Infrared Technology, Volume. 45, Issue 11, 1236(2023)

Analysis of Calibration Method and Occasion of Ground-based Infrared Imaging Equipments with Different FOVs

Qianjin ZOU, Hengwei ZHANG, Dong WANG, Xiaohu LIU, and Zhuangzhuang TIAN
Author Affiliations
  • [in Chinese]
  • show less

    We can use the infrared radiation characteristics of a target for target recognition. Data on infrared radiation characteristics obtained by out-field infrared imaging equipment is significant in evaluating early warning, reconnaissance, and stealth effects. It is difficult to obtain the response coefficients of out-field infrared imaging equipment. We introduced and compared radiometric calibration methods using a collimator and an extended-area blackbody. We conducted experiments using different calibration methods and then provided response coefficients of the out-field infrared imaging equipment. The long-distance radiometric calibration results showed different response coefficients at different distances. An infrared imaging system conducted calibration experiments with different working times and fusions. The radiometric out-of-focus calibration results showed that diffusion is not the main factor influencing calibration. Calibration experiments for different working times also showed that the response coefficients remained unchanged. The factors affecting the radiometric calibration of the out-field infrared imaging equipment are environmental radiation, path radiation, and path transmission. Short-distance radiometric calibration using an extended-area blackbody is necessary to obtain the response coefficients of the out-field infrared imaging equipment. If the radiometric calibration distance is less than 10 m, the error between the short-and long-distance radiometric calibrations is approximately 5%. This research helps out-field radiometric calibration of ground-based infrared imaging equipment and designs a radiometric calibration–measuring system.

    Tools

    Get Citation

    Copy Citation Text

    ZOU Qianjin, ZHANG Hengwei, WANG Dong, LIU Xiaohu, TIAN Zhuangzhuang. Analysis of Calibration Method and Occasion of Ground-based Infrared Imaging Equipments with Different FOVs[J]. Infrared Technology, 2023, 45(11): 1236

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category:

    Received: Jun. 10, 2022

    Accepted: --

    Published Online: Jan. 17, 2024

    The Author Email:

    DOI:1001-8891(2023)11-1236-06

    Topics