Infrared and Laser Engineering, Volume. 44, Issue 11, 3270(2015)

A composite scanning method and experiment of laser radar

Ma Chenhao*, Fu Yuegang, Gong Ping, Ouyang Mingzhao, and Zhang Shuhan
Author Affiliations
  • [in Chinese]
  • show less

    In traditional laser radar system, the imaging is influenced by repetition rate of selected solid-state laser as well as scanning bandwidth and scanning precision in the laser scanning system. In order to improve the scanning bandwidth and precision, DFB high-repetition-rate semiconductor laser which was amplified by EDFA was adopted as the laser source firstly. Secondly, a two-stage composite laser scanning method had been proposed with combination of PZT and galvanometer. PZT got on meticulous scanning in small areas, then galvanometer was used to deflect and finish coarse scanning on the PZT scanning field and receiving the field. The scanning accuracy had been raised and the scanning field of laser radar had been expanded simultaneously. At last, azimuth of composite scanning laser radar is ±99 mrad, pitch angle is ±49.5 mrad. Angular resolution can measure up to 0.1 mrad, and the ranging precision can reach 0.159 m.

    Tools

    Get Citation

    Copy Citation Text

    Ma Chenhao, Fu Yuegang, Gong Ping, Ouyang Mingzhao, Zhang Shuhan. A composite scanning method and experiment of laser radar[J]. Infrared and Laser Engineering, 2015, 44(11): 3270

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: 激光技术及应用

    Received: Mar. 21, 2015

    Accepted: Apr. 23, 2015

    Published Online: Jan. 26, 2016

    The Author Email: Chenhao Ma (mch6567@163.com)

    DOI:

    Topics