    As an emerging molecular imaging modality, cone-beam X-ray luminescence computed tomography (CB-XLCT) uses X-ray-excitable probes to produce near-infrared (NIR) luminescence and then reconstructs three-dimensional (3D) distribution of the probes from surface measurements. A proper photon-transportation model is critical to accuracy of XLCT. Here, we presented a systematic comparison between the common-used Monte Carlo model and simplified spherical harmonics (SPN). The performance of the two methods was evaluated over several main spectrums using a known XLCT material. We designed both a global measurement based on the cosine similarity and a locally-averaged relative error, to quantitatively assess these methods. The results show that the SP3 could reach a good balance between the modeling accuracy and computational e±ciency for all of the tested emission spectrums. Besides, the SP1 (which is equivalent to the diffusion equation (DE)) can be a reasonable alternative model for emission wavelength over 692 nm. In vivo experiment further demonstrates the reconstruction performance of the SP3 and DE. This study would provide a valuable guidance for modeling the photon-transportation in CB-XLCT.

    Tools

    Get Citation

    Copy Citation Text

    Haibo Zhang, Guohua Geng, Yanrong Chen, Fengjun Zhao, Yuqing Hou, Huangjian Yi, Shunli Zhang, Jingjing Yu, Xiaowei He. Performance evaluation of the simplified spherical harmonics approximation for cone-beam X-ray luminescence computed tomography imaging[J]. Journal of Innovative Optical Health Sciences, 2017, 10(3): 1750005

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Received: Sep. 23, 2016

    Accepted: Dec. 14, 2016

    Published Online: Dec. 27, 2018

    The Author Email: Geng Guohua (ghgeng@nwu.edu.cn)

    DOI:10.1142/s1793545817500055

    Topics