High Power Laser and Particle Beams, Volume. 34, Issue 5, 056009(2022)
Size measurements of beryllium assemblies after long term service
Beryllium is an important material as neutron reflection layers in nuclear reactors. The size change of beryllium after long term neutron irradiation has a great influence on the reactor safety. To obtain the size change of beryllium assemblies after long-time irradiation for the assessment of service performance, a set of special tools were designed and manufactured. The size change of post-irradiation beryllium assemblies was examined on a three coordinate measuring machine. The measurement results indicate that beryllium assemblies of the SPRR-300 reactor have excellent stability after 29 a irradiation, even under the maximum neutron fluence of 6.78×1021 cm-2. The section dimension has little change in local part of beryllium assemblies and the largest change is about 0.13 mm, which indicates that irradiation creep is the main reason for the dimension change of beryllium assemblies during the long-time service.
Get Citation
Copy Citation Text
Xiao Liu, Wankui Yang, Hao Wang, Jian Wang, Songbao Zhang, Xinrong Zhang, Wenhua Li. Size measurements of beryllium assemblies after long term service[J]. High Power Laser and Particle Beams, 2022, 34(5): 056009
Category: Feature Issue on Application Technology of Research Reactor
Received: Nov. 24, 2021
Accepted: --
Published Online: Jun. 2, 2022