Infrared and Laser Engineering, Volume. 32, Issue 4, 343(2003)

Power of small-scale CW discharge DF/HF chemical laser

[in Chinese]*, [in Chinese], [in Chinese], and [in Chinese]
Author Affiliations
  • [in Chinese]
  • show less

    The mixture of SF6 O2 and He which are regulated is injected into a discharge tube with 8 high-voltage electrodes. The divided F is injected into throat along flow direction. H2/D2 is injected along a long normal to the flow at the top and the bottom of the channel. The optical axis is located at 1 mm downstream of H2/D2 injectors. A small-scale continuous-wave DF/HF chemical laser is investigated. Experimental measurements indicate that its multiline output power is related to the flux of SF6, He and H2/D2. The effect on output power and laser device of O2 addition is investigated. The maximum net outputs of HF and DF are 12 W and 11 W respertively. The power is stable and regulated continuously, and the maximum operation time is 20 min.

    Tools

    Get Citation

    Copy Citation Text

    [in Chinese], [in Chinese], [in Chinese], [in Chinese]. Power of small-scale CW discharge DF/HF chemical laser[J]. Infrared and Laser Engineering, 2003, 32(4): 343

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category:

    Received: Oct. 10, 2002

    Accepted: Dec. 20, 2002

    Published Online: Apr. 28, 2006

    The Author Email:

    DOI:

    Topics