High Power Laser and Particle Beams, Volume. 36, Issue 7, 074004(2024)

Scattering correction method for cone-beam X-ray CT based on slanted-hole scattering correction plate

Chenglong Guo... Peijun Ni*, Zicheng Qi and Kang Fu |Show fewer author(s)
Author Affiliations
  • The Ningbo Branch of Ordnance Science Institute of China, Ningbo 315000, China
  • show less

    Compared with two-dimensional fan-beam and parallel-beam CT systems, cone-beam X-ray CT has advantages such as fast scanning speed, high X-ray utilization efficiency, consistent axial and horizontal resolution of reconstructed images, and is the focus of current industrial CT technology development. However, the imaging quality is affected by the presence of scattered radiation. To reduce the impact of scattered radiation on image quality, this paper proposes a new scatter correction method based on a slanted-hole scatter correction plate. The principle and implementation of this method are thoroughly investigated. By acquiring the raw scan data and the scan data after using the slanted-hole scatter correction plate, scatter field data is obtained using interpolation and smoothing techniques. Then, by subtracting the scatter field data from the original data and performing reconstruction, scatter-free CT images can be obtained. Compared with the grating-based scatter correction plate method, the results show that in cone-beam CT scans of turbine blades, the contrast-to-noise ratio of typical regions (the cooling channels within the blades and the inner walls of the blades) is improved by 14.2% and 56.8% respectively with the slanted-hole scatter correction plate method, whereas with the grating-based scatter correction plate method, the same positions only show an improvement of 5.6% and 27.6% respectively. This validates the superiority of the slanted-hole scatter correction plate scatter correction method.

    Keywords
    Tools

    Get Citation

    Copy Citation Text

    Chenglong Guo, Peijun Ni, Zicheng Qi, Kang Fu. Scattering correction method for cone-beam X-ray CT based on slanted-hole scattering correction plate[J]. High Power Laser and Particle Beams, 2024, 36(7): 074004

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category:

    Received: Oct. 20, 2023

    Accepted: Apr. 2, 2024

    Published Online: Jun. 21, 2024

    The Author Email: Ni Peijun (nipeijun@vip.sina.com)

    DOI:10.11884/HPLPB202436.230362