Infrared Technology, Volume. 45, Issue 2, 123(2023)

Analysis of the In-Orbit Radiation Calibration of SWIR Remote Sensing System Combined with Blackbody and Star

Libing JIN1,2、*, Xiaoman LI1,2, Minlong LIAN1,2, Huiting GAO1,2, and Ji ZHOU1,2
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less

    Considering the demand for high-precision detection of SWIR remote sensing systems, the demand for the quantitative application of SWIR detection has increased in recent years. The change in inhomogeneity caused by shortwave infrared remote sensor was analyzed. The design scheme of non-point source blackbody calibration combined with star calibration in-orbit absolute radiation calibration; the actual development process of a remote sensing task; and the main influencing factors and optimization measures, including the optimization of the satellite calibration scheme, optimization of satellite blackbody temperature control, and star extraction algorithm, were analyzed. Based on the results of laboratory tests and estimation of the accuracy of the absolute radiation calibration, the evaluation results show that the calibration accuracy can meet the application requirements.

    Tools

    Get Citation

    Copy Citation Text

    JIN Libing, LI Xiaoman, LIAN Minlong, GAO Huiting, ZHOU Ji. Analysis of the In-Orbit Radiation Calibration of SWIR Remote Sensing System Combined with Blackbody and Star[J]. Infrared Technology, 2023, 45(2): 123

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category:

    Received: Mar. 19, 2022

    Accepted: --

    Published Online: Mar. 20, 2023

    The Author Email: Libing JIN (jlb_99148@126.com)

    DOI:

    Topics