Journal of Atmospheric and Environmental Optics, Volume. 9, Issue 1, 50(2014)

Onboard Radiometric Calibration Method for HJ-1B Satellite Thermal Infrared Channel’s Each Detector

Li LIU1、*, Qi-jin HAN1, Ting-ting SHI2, Ai-chun WANG1, and Xue-wen ZHANG1
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less

    Onboard calibration accuracy of HJ-1B Satellite thermal infrared channel directly affects the quantitative application of remote sensing data. The response differences of each detector were ignored by the previous onboard calibration methods which focused on the whole channel. The look-up table, half-width and moments methods are used to calculate each detector’s calibration coefficients of HJ-1B thermal infrared channel based on the blackbody data transferred on Sep. 14th, 2009. The results show that the deviation is about 2 DN when the detectors scanning the adaptive blackbody, which bring errors from 0.28% to 0.45%. The 9th and 10th detectors have larger deviation than the others.

    Tools

    Get Citation

    Copy Citation Text

    LIU Li, HAN Qi-jin, SHI Ting-ting, WANG Ai-chun, ZHANG Xue-wen. Onboard Radiometric Calibration Method for HJ-1B Satellite Thermal Infrared Channel’s Each Detector[J]. Journal of Atmospheric and Environmental Optics, 2014, 9(1): 50

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Received: Oct. 28, 2013

    Accepted: --

    Published Online: Feb. 18, 2014