Infrared and Laser Engineering, Volume. 44, Issue 12, 3576(2015)

Smile effect of laser diode arrays measured by stylus scan method

Jia Guannan*, Yao Shun, Pan Fei, Gao Xiangyu, and Wang Zhiyong
Author Affiliations
  • [in Chinese]
  • show less

    Traditional optical methods which are used to measure the Smile effect of laser diode arrays(LDA) have problems such as high precision optical system setting up, high operator quality requirements, vast and complex subsequent data processing, long measuring time and so on. In this paper, a new method that scanned the N side of mounted LDA chips with the stylus of a mechanical contacting profiler was proposed to measure the Smile effect of LDA quickly. The measuring result was compared with the Smile effect measured by a traditional optical method. And the comparision indicates that their shapes are uniform and the difference is less than 1 micrometre. Using a profiler to measure the Smile effect of LDA takes little time less than 1 minute. The method can provide feedbacks quickly in chips bonding process to minimize the Smile effect, and can be easily integrated into high production lines to monitor the Smile effect of laser diode arrays in real time.

    Tools

    Get Citation

    Copy Citation Text

    Jia Guannan, Yao Shun, Pan Fei, Gao Xiangyu, Wang Zhiyong. Smile effect of laser diode arrays measured by stylus scan method[J]. Infrared and Laser Engineering, 2015, 44(12): 3576

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: 激光技术及应用

    Received: Apr. 7, 2015

    Accepted: May. 13, 2015

    Published Online: Jan. 26, 2016

    The Author Email: Guannan Jia (jiaguannan@emails.bjut.edu.cn)

    DOI:

    Topics