Optics and Precision Engineering, Volume. 22, Issue 10, 2779(2014)
Target filament accurate restoring system in high-energetic particle burst experiment
In consideration of the demand of bremsstrahlung conversion target filament for accurate restoring in high-energetic particle burst experiments,a service device for target filament accurate restoring was designed. First, some key formulas of restoring system were derived according to the stereoscopic theory. Then, a scheme for design of an accurate restoring system of the micro target filament was proposed according to the real application. Finally, an experiment platform to simulate real conditions was established to test the restoring accuracy error of this system. The experiment results indicate that the accuracy error of this restoring system is 2%.The semi-physical simulation experiment illustrates that this restoring system reaches the accurate restoring of the bremsstrahlung conversion target filament in the high-energetic particle burst experiments. As the research object is a restoring system rather than a positioning system, it do not need to be calibrated, so there is no calibration error. The target filament accurate restoring system developed ensures the reliability of high energy electron beam burst experiments.
Get Citation
Copy Citation Text
ZHANG Yuan, ZHONG Xing, XU Zhen, JIN Guang. Target filament accurate restoring system in high-energetic particle burst experiment[J]. Optics and Precision Engineering, 2014, 22(10): 2779
Category:
Received: Dec. 3, 2013
Accepted: --
Published Online: Nov. 6, 2014
The Author Email: Yuan ZHANG (zhangyuanfresh@126.com)