High Power Laser and Particle Beams, Volume. 36, Issue 10, 106003(2024)

Research on Monte Carlo calculation method for photon absorbed dose

Rong Xie1, Jianhong Hao1, Qiang Zhao2、*, Fang Zhang2, Jieqing Fan1, Bixi Xue2, Zhiwei Dong2, and Xiangchun Cao1
Author Affiliations
  • 1School of Electrical and Electronic Engineering, North China Electric Power University, Beijing 102206, China
  • 2Institute of Applied Physics and Computational Mathematics, Beijing 100094, China
  • show less

    To accurately and effectively calculate and evaluate photon doses under different radiation conditions by selecting appropriate calculation methods, this paper compares and studies four commonly used photon dose calculation methods in Monte Carlo simulation software: dose conversion coefficient method, heat number method, track length energy deposition method and pulse height method. Starting from the calculation principle and combining simulation results, these four methods are analyzed and compared. By simulating single energy photon beams with different energies incident on water spheres of different volume sizes, the error caused by approximating absorbed dose with kerma was analyzed, and the influence of different contents of high atomic number element gadolinium on absorbed dose calculation results was simulated and analyzed. Due to the fact that the conversion coefficient is calculated based on the reference human model, the dose conversion coefficient method can only quickly estimate and calculate the absorbed dose, it is difficult to obtain accurate dose in specific situations. When high-energy photons are incident on a small volume of material, kerma will be greater than the absorbed dose, thus the heat number method and the track length energy deposition method will produce errors, and the pulse height counting method is more suitable. At low energy and large volume, any method can be selected based on computational accuracy and computer resources. When the content of high atomic number elements in a substance increases, the calculation error between the track length energy deposition method and the pulse height method will decrease.

    Keywords
    Tools

    Get Citation

    Copy Citation Text

    Rong Xie, Jianhong Hao, Qiang Zhao, Fang Zhang, Jieqing Fan, Bixi Xue, Zhiwei Dong, Xiangchun Cao. Research on Monte Carlo calculation method for photon absorbed dose[J]. High Power Laser and Particle Beams, 2024, 36(10): 106003

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Special Column of 4th Symposium on Frontier of HPLPB

    Received: May. 25, 2024

    Accepted: Aug. 25, 2024

    Published Online: Nov. 13, 2024

    The Author Email: Zhao Qiang (zhaoq@iapcm.ac.cn)

    DOI:10.11884/HPLPB202436.240037

    Topics