Acta Photonica Sinica, Volume. 41, Issue 10, 1149(2012)

Heterodyne Laser Doppler Vibrometer Based on Double Acousto-optic Frequency Shifters

SHANG Jian-hua1、*, REN Li-hong1, XU Hai-qin1, ZHAO Shu-guang1, and HE Yan2
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less

    The influence on the measured vibration signal caused by the frequency-stability and signal power of driver signal to acousto-optic frequency shifter (AOFS) in the high-precision heterodyne laser doppler vibrometry (HLDV) with one AOFSs was analyzed. In order to reduce the frequency drifting and the phase noise of the driver signal, the HLDV composed with two AOFSs was proposed. And based on the direct digital frequency synthesis (DDS) technology, the design of the driving signal generation unit has been completed with AD9912 which has the characteristic of adjustable initial-phase and low phase noise. The vibration-measuring experiments performed with HLDV consists of two AOFS shows that the designed generation unit is able to drive the AOFS. Meantime, compared with the HLDV with one AOFS, the noise floor from 0 to 10 kHz of the HLDV with two AOFS is flat and the noise distribution below 1 kHz has been depressed greatly.

    Tools

    Get Citation

    Copy Citation Text

    SHANG Jian-hua, REN Li-hong, XU Hai-qin, ZHAO Shu-guang, HE Yan. Heterodyne Laser Doppler Vibrometer Based on Double Acousto-optic Frequency Shifters[J]. Acta Photonica Sinica, 2012, 41(10): 1149

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Received: May. 16, 2012

    Accepted: --

    Published Online: Nov. 7, 2012

    The Author Email: Jian-hua SHANG (jhshang@dhu.du.cn)

    DOI:10.3788/gzxb20124110.1149