Infrared and Laser Engineering, Volume. 47, Issue 11, 1117002(2018)

Detection system of CO2 using hollow-core crystal fiber based on LabVIEW

Lv Shuyuan* and Du Shaoyong
Author Affiliations
  • [in Chinese]
  • show less

    For the purpose of realizing the all-fiber gas detection system with high sensor sensitivity, using the Hollow Core-Photonic Crystal Fiber (HC-PCF) as gas cell, a dual-optical path differential near-infrared carbon dioxide detection experimental system based on virtual instruments LabVIEW and the absorption spectroscopy around wavelength 1 572.48 nm of carbon dioxide molecule was developed. The system response time was about 100 s by inflating the HC-PCF of 1.8 m long from two ends under the pressure of 0.1 MPa. The detection system was calibrated with carbon dioxide of standard concentration. Carbon dioxide with known concentration of 2%, 5%, 10% and 100% were tested respectively and the experimental results showed that the detection errors relative to standard concentration were no more than 2% and the maximum standard deviation of measured concentration were 3.32% in 100 minutes. In addition, the optical path of gas absorption reaches 1.8 m and the system detection sensitivity of 5.981 8×10-5 μW/ppm was achieved.

    Tools

    Get Citation

    Copy Citation Text

    Lv Shuyuan, Du Shaoyong. Detection system of CO2 using hollow-core crystal fiber based on LabVIEW[J]. Infrared and Laser Engineering, 2018, 47(11): 1117002

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: 光电测量

    Received: Jun. 5, 2018

    Accepted: Jul. 3, 2018

    Published Online: Jan. 10, 2019

    The Author Email: Shuyuan Lv (1159955131@qq.com)

    DOI:10.3788/irla201847.1117002

    Topics