INFRARED, Volume. 42, Issue 5, 13(2021)

Design and Experimental Research for Improving Temperature Control Precision of Bellows-type Self-regulating J-T Cooler

Yan-hong MA1、* and Zhi-hong GONG2
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less

    In order to improve the temperature control precision of the bellows-type J-T cooler, the needle design is optimized. The tip of the needle is grooved to form double throttled holes with the main throttled hole on the valve body of the cooler. The working medium enters the main throttled hole for throttling and cooling after the start. The hole is completely blocked by the needle after self-regulating of the cooler, and the steady small flow is ejected from the groove.The reasonable size of the groove is determined. The test results show that the groove on the tip of the needle can effectively improve the temperature control precision.

    Tools

    Get Citation

    Copy Citation Text

    MA Yan-hong, GONG Zhi-hong. Design and Experimental Research for Improving Temperature Control Precision of Bellows-type Self-regulating J-T Cooler[J]. INFRARED, 2021, 42(5): 13

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category:

    Received: Nov. 19, 2020

    Accepted: --

    Published Online: Aug. 16, 2021

    The Author Email: Yan-hong MA (470594486@qq.com)

    DOI:10.3969/j.issn.1672-8785.2021.05.003