Journal of Atmospheric and Environmental Optics, Volume. 11, Issue 5, 383(2016)

Analysis on Optimal Detection Time of Laser-Induced Breakdown Spectroscopy

Yang YU, Nanjing ZHAO*, Li FANG, Deshuo MENG, Yanhong GU, Yuanyuan WANG, Yao JIA, Mingjun MA, Jianguo LIU, and Wenqing LIU
Author Affiliations
  • [in Chinese]
  • show less

    In order to determine the optimal detection time of laser-induced breakdown spectroscopy(LIBS), time-resolved LIBS technique has been adopted to study the decay characteristics of peak intensity and spectral intensity of four elements Fe, Pb, Ca and Mg contained in the sample. The extreme value of ratio of peak intensity of characteristic lines and spectral intensity of continuous radiation is calculated, and the calculation value of time corresponding to the optimal signal-to-background ratio (SBR) of characteristic lines is obtained. The peak intensity of characteristic lines and spectral intensity of continuous radiation both decay in exponential form, the decay time of four characteristic lines are 1.42, 1.95, 1.69, 1.65 μs, and the corresponding decay time of continuous radiation are 0.85, 0.93, 0.89, 0.87 μs respectively. The calculation value of corresponding time of optimal SBR of four characteristic lines are 1.43, 1.77, 1.62, 1.80 μs, and experimental measurement value of corresponding time of optimal SBR are 1.5, 2.0, 1.5, 1.5 μs. They have a good consistency. The corresponding time of optimal SBR can be predicted by evolution law of peak intensity of characteristic lines and spectral intensity of continuous radiation. The results indicate that the optimal detection time of LIBS is closely related to decay law of continuous radiation and characteristic lines, and the corresponding time of optimal SBR of spectral lines can be predicted by evaluating extreme value of the ratio of spectral intensity. The method provides the basis for selecting the optimal time of LIBS detection and analysis.

    Tools

    Get Citation

    Copy Citation Text

    YU Yang, ZHAO Nanjing, FANG Li, MENG Deshuo, GU Yanhong, WANG Yuanyuan, JIA Yao, MA Mingjun, LIU Jianguo, LIU Wenqing. Analysis on Optimal Detection Time of Laser-Induced Breakdown Spectroscopy[J]. Journal of Atmospheric and Environmental Optics, 2016, 11(5): 383

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Received: Apr. 27, 2016

    Accepted: --

    Published Online: Oct. 20, 2016

    The Author Email: Nanjing ZHAO (njzhao@aiofm.ac.cn)

    DOI:10.3969/j.issn.1673-6141.2016.05.006

    Topics