Acta Optica Sinica, Volume. 13, Issue 6, 490(1993)
Calculation and measurement on the CL spectral effective collected-efficiency of rotational semi-ellipsoid mirror
In this paper, the calculation formulas on the CL spectral effective collected-efficiency of rotational semi-ellipsoid mirror are derived under the uniform luminescence model of a point source, and the relationship between its collected efficiency and ellipsoid parameter, CL collected angle, exit angle, azimuth angle of the exit-beam, etc are analysed. The theoretical calculation and experimental results are given and they are in good agreement conclusions.
Get Citation
Copy Citation Text
[in Chinese], [in Chinese], [in Chinese]. Calculation and measurement on the CL spectral effective collected-efficiency of rotational semi-ellipsoid mirror[J]. Acta Optica Sinica, 1993, 13(6): 490