Acta Optica Sinica, Volume. 42, Issue 4, 0434001(2022)

Non-Null Interferometric Test of X-Ray Cylindrical Reflect Mirror

Ting Deng1,2, Fengwei Liu1、*, Die Qin1,2, Yan Xu1, Yongqian Wu1, and Qiang Chen1
Author Affiliations
  • 1Institute of Optics and Electronics, Chinese Academy of Sciences, Chengdu, Sichuan 610209, China
  • 2University of Chinese Academy of Sciences, Beijing 100049, China
  • show less

    In this paper, a non-null interferometric measurement method of X-ray mirror is proposed, which can achieve high precision interferometric measurement of zero ratrace error without splicing. A high precision plane mirror is used to calibrate the ratrace error of the interference system in the full field of view. By dividing the aspherical mirror into several sub-apertures, each sub-aperture can be approximately regarded as a plane, so that the ratrace error corresponding to the sub-aperture can be found from the calibration database, and the ratrace error of the entire aspherical mirror can be obtained by simple matrix splicing. Taking the X-ray elliptic cylindrical mirror as an example, the ratrace error of the non-null interferometric surface shape of the X-ray elliptic cylindrical mirror is effectively calibrated. Compared with the splicing interferometric method, the results of the two methods are consistent, which confirms the correctness of the proposed method.

    Tools

    Get Citation

    Copy Citation Text

    Ting Deng, Fengwei Liu, Die Qin, Yan Xu, Yongqian Wu, Qiang Chen. Non-Null Interferometric Test of X-Ray Cylindrical Reflect Mirror[J]. Acta Optica Sinica, 2022, 42(4): 0434001

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: X-Ray Optics

    Received: Jun. 29, 2021

    Accepted: Aug. 20, 2021

    Published Online: Jan. 29, 2022

    The Author Email: Liu Fengwei (fengweiliu@126.com)

    DOI:10.3788/AOS202242.0434001

    Topics