Acta Optica Sinica, Volume. 42, Issue 1, 0112004(2022)

Calibration System of Sunshine Duration Recorder Based on Bi-Xenon Lamp Source Integrating Sphere

Wei Chong1,2, Wenhua Lü1,2、*, Jian Zhang1,3,4, Jing Liang1, Xiaotong Yang1, Shi Liu1,3,4, Guoyu Zhang1,3,4, and Kesan Yang5
Author Affiliations
  • 1School of Opto-Electronic Engineering, Changchun University of Science and Technology, Changchun, Jilin 130022, China
  • 2Meteorological Observation Center of China Meteorological Administration, Beijing 100081, China
  • 3Key Laboratory of Opto-Electronic Measurement and Optical Information Transmission Technology, Ministry of Education, Changchun, Jilin 130022, China
  • 4Jilin Engineering Research Center of Photoelectronic Measurement & Control Instruments, Changchun, Jilin 130022, China;
  • 5Aerospace Newsky Technology Co. Ltd., Wuxi, Jiangsu 214127, China
  • show less

    Given the environmental influence, poor repeatability, and low efficiency of the outdoor calibration of the rotating pyroelectric sunshine duration recorder (RPSDR), an indoor calibration method using RPSDR with a system of the bi-xenon lamp source integrating sphere was proposed. According to the composition, structure, and measurement principle of the RPSDR, a calibration system based on the bi-xenon lamp source integrating sphere with the xenon lamp solar simulator outputting direct radiation and the dome xenon lamps simulating diffuse radiation was designed by technologies such as solar simulation and environmental simulation with the integrating sphere. The structural parameters of the integrating sphere were putforward, and the irradiance distribution and spectral correction of the xenon lamp source were analyzed. A comprehensive RPSDR calibration method for indoor sunshine threshold calibration and outdoor sunshine duration verification was established. According to the tests, the irradiance uniformity on the effective irradiation surface of the calibration system was 2.5% with the center point and 1.6% without the center point. On the effective irradiation surface, the irradiance stability per hour at the threshold point was 0.68%, and the light source matched with the AM1.5 class A solar spectral energy distribution. Experiments of indoor threshold calibration and outdoor sunshine duration comparison were carried out on an RPSDR. The results show that the relative error of sunshine duration measured with the RPSDR after calibration is less than 1% and the absolute error is no more than 0.26 h compared with the reference values measured with the pyrheliometer, which meet the requirements of the meteorological industry for sunshine duration observation.

    Tools

    Get Citation

    Copy Citation Text

    Wei Chong, Wenhua Lü, Jian Zhang, Jing Liang, Xiaotong Yang, Shi Liu, Guoyu Zhang, Kesan Yang. Calibration System of Sunshine Duration Recorder Based on Bi-Xenon Lamp Source Integrating Sphere[J]. Acta Optica Sinica, 2022, 42(1): 0112004

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Instrumentation, Measurement and Metrology

    Received: May. 10, 2021

    Accepted: Jul. 13, 2021

    Published Online: Dec. 22, 2021

    The Author Email: Lü Wenhua (lwhaoc@cma.cn)

    DOI:10.3788/AOS202242.0112004

    Topics