Infrared and Laser Engineering, Volume. 51, Issue 6, 20210472(2022)

Calibration method of liquid lens focusing system for machine vision measurement

Yang Li1,2, Guoming Wang1,2, Ying Wang1,2, Zhi Cheng1,2, Weihu Zhou1,2、*, and Dengfeng Dong1,2、*
Author Affiliations
  • 1Institute of Microelectronics, Chinese Academy of Sciences, Beijing 100094, China
  • 2University of Chinese Academy of Sciences, Beijing 100049, China
  • show less

    High performance optical imaging device is an important basis for machine vision measurement, as a compact and fast electronic controlled focusing device, liquid lens has a promising application in the field of machine vision measurement. In practical, the performance of liquid lens focusing device is easily interfered by the environment, and the intrinsic parameters are difficult to be calibrated accurately, which limits their application in machine vision measurement. The problems described above were researched, a machine vision measurement system was built based on Optotune's liquid lens. By analyzing the electronically controlled focusing mechanism of liquid lens, the model between current and focal length was proposed. Then the interaction mechanism between system parameters and temperature factor and gravity factors was studied, followed by the proposition of temperature-focal length model and gravity-main point vertical position model. By combining the system models with pin-hole imaging model, a functional expression of system intrinsic parameters was proposed, and the corresponding calibration device and calibration process to acquire all the coefficients of the expression were designed and verified through experiment. Finally, to evaluate parameter calibration accuracy, measurement test was performed using a checkerboard with sides of 30 mm. Test results show that the proposed calibration method can get more accurate intrinsic parameters, the average positional error of image corner points' world coordinate mapping result is 0.10 mm, meanwhile the maximum relative error of the length of the side of checkerboard is 0.68%, the errors are reduced by 27.2% and 54.4% respectively compared with test results using intrinsic parameters calibrated by mostly used interpolation method.

    Tools

    Get Citation

    Copy Citation Text

    Yang Li, Guoming Wang, Ying Wang, Zhi Cheng, Weihu Zhou, Dengfeng Dong. Calibration method of liquid lens focusing system for machine vision measurement[J]. Infrared and Laser Engineering, 2022, 51(6): 20210472

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Photoelectric measurement

    Received: Jul. 13, 2021

    Accepted: --

    Published Online: Dec. 20, 2022

    The Author Email: Zhou Weihu (zhouweihu@ime.ac.cn), Dong Dengfeng (dongdengfeng@ime.ac.cn)

    DOI:10.3788/IRLA20210472

    Topics