Acta Photonica Sinica, Volume. 50, Issue 2, 122(2021)

Experimental Study on Methane Detection Based on Cascaded Integrator Comb of Digital Orthogonal Phase-locked in Amplifier

Guolin LI, Qingzhi JIANG, Kun MA, Yue JIAO, and Wenhai JI
Author Affiliations
  • College of Control Science and Engineering, China University of Petroleum (East China), Qingdao, Shandong266580, China
  • show less

    Aiming at the problems of complicated background gas composition, difficult detection, and poor stability of methane in the atmosphere, based on tunable diode laser absorption spectroscopy technology and wavelength modulation spectroscopy technology, the cascaded integrator comb filter and finite impulse response filter are applied to the digital quadrature lock-in amplifier to investigate experimental research on trace detection of methane gas in the atmosphere in this paper. Experiments show that compared with the traditional digital quadrature lock-in amplifier, the signal-noise ratio of the second harmonic signal extracted by the improved digital quadrature lock-in amplifier is improved from 38.61 dB to 44.95 dB; Applying the nonlinear iteration partial least square-extreme learning machine algorithm model to the methane gas concentration inversion, compared with the classic least square method, the root mean square error decreases by 0.907. Through 16 sets of concentration step-by-step experiment tests, the actual detection limit of the system is 1 ppm; The long-term stability test is conducted at 600 mbar pressure, 25 ℃ and 50 ppm methane concentration for 3 hours. The variation range of methane concentration detected is 49.6 ppm~50.3 ppm, and the standard deviation is 0.092 1 ppm. When the integration time reaches 56 s, the theoretical detection limit of the system is 25.6 ppb. This shows that the cascaded integrator comb filter and the nonlinear iteration partial least square-extreme learning machine algorithm model have higher superiority and practical prospects in infrared gas detection.

    Tools

    Get Citation

    Copy Citation Text

    Guolin LI, Qingzhi JIANG, Kun MA, Yue JIAO, Wenhai JI. Experimental Study on Methane Detection Based on Cascaded Integrator Comb of Digital Orthogonal Phase-locked in Amplifier[J]. Acta Photonica Sinica, 2021, 50(2): 122

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Instrumentation, Measurement and Metrology

    Received: --

    Accepted: --

    Published Online: Aug. 26, 2021

    The Author Email:

    DOI:10.3788/gzxb20215002.0212001

    Topics