High Power Laser and Particle Beams, Volume. 32, Issue 5, 052002(2020)

Experiment study of extended X-ray absorption fine structure spectrum on SG-III prototype facility

Yun Hu... Jiyan Zhang, Shaoen Jiang*, Zhebin Wang and Yudong Pu |Show fewer author(s)
Author Affiliations
  • Research Center of Laser Fusion, CAEP, P. O. Box 919-986, Mianyang 621900, China
  • show less

    This article intoduces the principle of extended X-ray absorption fine structure(EXAFS) as parameter diagnostic method on large laser facilities, as well as the experiments on SG-III prototype facility for high quality EXAFS. Using glass ball, CH capsule and Au ball as backlighters, through multi-shots accumulation method, EXAFS of Ti in ambient condition with good signal-to-noise ratio were obtained. The experiment results coincide well with the results of the synchrotron radiation experiment, indicating the correctness and reliability of the experimental design. Analysis of the results show the factors affecting the EXAFS spectrum quality are photon counts, spectral resolution, noise and flaws on apparatuses.