Acta Photonica Sinica, Volume. 39, Issue 11, 2068(2010)
Thermaloptical Analysis and Tests for High Resolution Space Camera
Temperature filed distributing of a high resolution space telescope is analyzed by thermaloptical method based on optical frontwaveerror theory, and thermal contral target is ascertained. The thermal tests in the vacuum are carried out to validate the analysis. Tests results indicate that the ideal focal plane position vs temperature level are linearity, and changes scope approximately 0.08~0.1 mm·℃-1. As the macrocosmic temperature changing within (20±1)℃, system MTF change about 0.02. When the temperature grads are more than 2 ℃ in axis direction and diameter direction, the ideal focal plane position departure happenes and the MTF decline obviously if unfocus.
Get Citation
Copy Citation Text
CHEN Rongli, MA Zhen, YANG Wengang, YU Lei, HE Tianbing, LI Yingcai. Thermaloptical Analysis and Tests for High Resolution Space Camera[J]. Acta Photonica Sinica, 2010, 39(11): 2068
Received: Apr. 6, 2010
Accepted: --
Published Online: Dec. 7, 2010
The Author Email: Rongli CHEN (crl@opt.ac.cn)
CSTR:32186.14.