Acta Photonica Sinica, Volume. 39, Issue 11, 2068(2010)

Thermaloptical Analysis and Tests for High Resolution Space Camera

CHEN Rongli1、*, MA Zhen1, YANG Wengang1, YU Lei2, HE Tianbing1, and LI Yingcai1
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less

    Temperature filed distributing of a high resolution space telescope is analyzed by thermaloptical method based on optical frontwaveerror theory, and thermal contral target is ascertained. The thermal tests in the vacuum are carried out to validate the analysis. Tests results indicate that the ideal focal plane position vs temperature level are linearity, and changes scope approximately 0.08~0.1 mm·℃-1. As the macrocosmic temperature changing within (20±1)℃, system MTF change about 0.02. When the temperature grads are more than 2 ℃ in axis direction and diameter direction, the ideal focal plane position departure happenes and the MTF decline obviously if unfocus.

    Tools

    Get Citation

    Copy Citation Text

    CHEN Rongli, MA Zhen, YANG Wengang, YU Lei, HE Tianbing, LI Yingcai. Thermaloptical Analysis and Tests for High Resolution Space Camera[J]. Acta Photonica Sinica, 2010, 39(11): 2068

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Received: Apr. 6, 2010

    Accepted: --

    Published Online: Dec. 7, 2010

    The Author Email: Rongli CHEN (crl@opt.ac.cn)

    DOI:

    Topics