Spectroscopy and Spectral Analysis, Volume. 37, Issue 10, 3225(2017)

Fast and Nondestructive Analysis of Content of Mercury and Arsenic and Homogeneity of Niuhuang Qingxin Pills by Portable X-Ray Fluorescence Spectrometry

NIE Li-xing1、*, ZHANG Ye2, ZHU Li1, DAI Zhong1, and MA Shuang-cheng1
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less

    Determination of inorganic elements in traditional Chinese medicine by conventional wet-chemistry approach is complex and time-consuming. The samples must be digested before instrumental analysis. For preparations containing cinnabaris or realgar, high content of Hg and As will contaminate lab wares and instruments. However, X-ray fluorescence spectrometry is simple, fast and can simultaneously determine multiple elements in a non-destructive way. In this paper, portable X-ray fluorescence spectrometry was applied to establish a novel method for rapid and nondestructive determination of Hg and As in Niuhuang Qingxin Pills. And the method was employed in homogeneity analysis of the drug for the first time. After optimization of the measurement mode, using the inductively coupled plasma-optical emission spectroscopy as the reference value, working calibration curve was obtained for determination. Experiments results showed that precision was high with relative standard deviation of 0.09% and 0.23%, respectively, and the determination results of Hg and As were close to the reference values with relative mean deviations of 8.58% and 5.95%, respectively, which met the requirements of on-site rapid screening. Results indicated that contents of Hg in 2 batches of the samples were abnormally low and contents of As in 1 batches of the samples was abnormally high. Sample from 1 manufacturer was inhomogeneous. The proposed method was quick, simple, economic and environment-friendly, which offered a new approach for quality control of traditional Chinese medicine containing mineral. The portable instrument brings high efficiency and high throughput, which can help revealing hidden danger of drug quality. In all, X-ray fluorescence spectrometry can save time, manpower and resources, and has a bright prospect in application.

    Tools

    Get Citation

    Copy Citation Text

    NIE Li-xing, ZHANG Ye, ZHU Li, DAI Zhong, MA Shuang-cheng. Fast and Nondestructive Analysis of Content of Mercury and Arsenic and Homogeneity of Niuhuang Qingxin Pills by Portable X-Ray Fluorescence Spectrometry[J]. Spectroscopy and Spectral Analysis, 2017, 37(10): 3225

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Received: Apr. 5, 2016

    Accepted: --

    Published Online: Dec. 25, 2017

    The Author Email: Li-xing NIE (nielixing@163.com)

    DOI:10.3964/j.issn.1000-0593(2017)10-3225-04

    Topics