Spectroscopy and Spectral Analysis, Volume. 44, Issue 11, 3109(2024)

Research of Chlorine Concentration Inversion Method Based on 1D-CNN Using Ultraviolet Spectral

JIA Tong-hua1... CHENG Guang-xu1,*, YANG Jia-cong1, CHEN Sheng2, WANG Hai-rong3 and HU Hai-jun1 |Show fewer author(s)
Author Affiliations
  • 1Department of Process Equipment and Control Engineering, School of Chemical and Technology, Xi’an Jiaotong University, Xi’an 710049, China
  • 2China Special Equipment Inspection & Research Institute, National Market Supervision Technology, Beijing 100029, China
  • 3State Key Laboratory of Machinery Manufacturing System, School of Mechanical Engineering, Xi’an Jiaotong University, Xi’an 710049, China
  • show less

    The accurate detection of chlorine leakage in an open environment has been an urgent problem for chlor-alkali manufacturers. Differential optical absorption spectroscopy (DOAS) can realize long-distance measurements of trace polluting gases in the atmosphere. Due to the flat characteristic of the UV absorption spectrum of chlorine, it is impossible to differentiate the absorption characteristics from the noise signal by normal methods. A new algorithm based on a one-dimensional convolutional neural network (1D-CNN) is proposed to solve the problem of poor accuracy caused by noise interference, which can fully use spectral information and extract chlorine absorption characteristics layer by layer. Compared with commonly used models such as least squares (LS), multilayer perceptron (MLP), support vector machine (SVR), and k-nearest neighbor (KNN), the inversion result of this algorithm has the highest accuracy (R2=0.996, RMSE=4.40, MAE=2.64, SMAPE=8.51%). Due to the inevitable random noise in -the system, the preprocessing effects of the S-G filter, Fourier transform, singular value decomposition, and wavelet transform decomposition algorithms are compared. The results show that S-G filtering and wavelet decomposition algorithms can retain the characteristic information of chlorine while removing noise and further improving the model’s performance. The concentration inversion model based on 1D-CNN provides a new feasible method for long-distance quantitative detection of chlorine leakage in the open environment.

    Tools

    Get Citation

    Copy Citation Text

    JIA Tong-hua, CHENG Guang-xu, YANG Jia-cong, CHEN Sheng, WANG Hai-rong, HU Hai-jun. Research of Chlorine Concentration Inversion Method Based on 1D-CNN Using Ultraviolet Spectral[J]. Spectroscopy and Spectral Analysis, 2024, 44(11): 3109

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Received: Sep. 21, 2023

    Accepted: Jan. 16, 2025

    Published Online: Jan. 16, 2025

    The Author Email: Guang-xu CHENG (gxcheng@xjtu.edu.cn)

    DOI:10.3964/j.issn.1000-0593(2024)11-3109-11