Chinese Journal of Lasers, Volume. 36, Issue 8, 2089(2009)

Analyses and Improvement of Scaling Method in Particle Field Holography

Cao Na1、*, Cao Liang1, Xu Qing1, Cui Guangbing1, Xue Jun2, Ma Jiming1, and Zhang Zhanhong1
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less

    For quantitative analysis in the particle field, a standard wire is generally used as the scaler for measuring the particle size. In order to understand the effect of the reconstructed wire with a certain depth of field on the experimental results, detail analysis of the intensity distribution and variation of the reconstructed wire at different positions are performed by theory and experiments. The influences of the normal scaling method on the particle image data are pointed out and a new scaling method, the non-in -time scaling manner, is given. Experiment results show that, the uncertainty of the particles size measurement is about 4% by keeping the precision of particle location. This new method can effectively solve the problem, which affects the precision of the particle size measurement. It can be used in practical measurements.

    Tools

    Get Citation

    Copy Citation Text

    Cao Na, Cao Liang, Xu Qing, Cui Guangbing, Xue Jun, Ma Jiming, Zhang Zhanhong. Analyses and Improvement of Scaling Method in Particle Field Holography[J]. Chinese Journal of Lasers, 2009, 36(8): 2089

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: holography and information processing

    Received: Jun. 20, 2008

    Accepted: --

    Published Online: Aug. 13, 2009

    The Author Email: Na Cao (cnt96@yahoo.com)

    DOI:

    Topics