Laser & Optoelectronics Progress, Volume. 49, Issue 12, 122204(2012)

Athermalization Design of Dual-Field-of-View Long Wavelength Infrared Optical System

Chen Jianfa1,2、*, Wang Helong1,2, Liu Xin2, and Pan Zhifeng2
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less

    A design study of athermalization of switchable dual-field-of-view optical systems for 7.7~9.7 μm is presented. With the axial motion of a lens group, a result of dual-field-of-view infrared optical system is achieved. In order to meet a wide environmental temperature range, the optical passive athermalization is used to eliminate the thermal effect in optical systems by correctly assembling different optical materials. The final optical designs along with their modulation transfer function (MTF) and root-mean-square (RMS) radius are presented, showing excellent imaging performance in dual fields-of-view at the temperature range between -60 ℃ and +70 ℃.

    Tools

    Get Citation

    Copy Citation Text

    Chen Jianfa, Wang Helong, Liu Xin, Pan Zhifeng. Athermalization Design of Dual-Field-of-View Long Wavelength Infrared Optical System[J]. Laser & Optoelectronics Progress, 2012, 49(12): 122204

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Optical Design and Fabrication

    Received: Aug. 13, 2012

    Accepted: --

    Published Online: Dec. 10, 2012

    The Author Email: Jianfa Chen (biterika@vip.qq.com)

    DOI:10.3788/lop49.122204