Optoelectronics Letters, Volume. 14, Issue 3, 179(2018)

Time constant optimization ofsolar irradiance absolute radiometer

TANGXiao 1...2,3, Wei FANG1,*, Yu-peng WANG1, Dong-jun YANG1 and Xiao-long and YI1 |Show fewer author(s)
Author Affiliations
  • 1Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China
  • 2University of Chinese Academy of Sciences, Beijing 100049, China
  • 3School of Mechanical Engineering, University of South China, Hengyang 421001, China
  • show less

    We experimentally evaluate and optimize the time constant of solar irradiance absolute radiometer (SIAR). The systemic error introduced by variable time constant is studied by a finite element method. The results shown that, with a classic time constant of 30 s for SIAR, the systemic errors are 0.06% in the midday and 0.275% in the morning and afternoon. The uncertainty level which can be considered negligible for SIAR is also investigated, and it is suggested that the uncertainty level has to be less than 0.02%. Then, combining the requirement of international comparison with these two conclusions, we conclude that the suitable time constant for SIAR is 20 s.

    Tools

    Get Citation

    Copy Citation Text

    TANGXiao, FANG Wei, WANG Yu-peng, YANG Dong-jun, and YI Xiao-long. Time constant optimization ofsolar irradiance absolute radiometer[J]. Optoelectronics Letters, 2018, 14(3): 179

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Devices

    Received: Nov. 18, 2016

    Accepted: Dec. 19, 2016

    Published Online: Sep. 15, 2018

    The Author Email: Wei FANG (tanggxiao1022@126.com)

    DOI:10.1007/s11801-017-7032-7