Infrared and Laser Engineering, Volume. 49, Issue 9, 20190551(2020)

Development of pressure control system for laser infrared multipass cell using Ziegler-Nichols-PID algorithm

Huixiang Xu* and Guoli Kong
Author Affiliations
  • School of Information Engineering, Zhengzhou Institute of Technology, Zhengzhou 450044, China
  • show less

    In order to realize the high performance detection of CO2 gas isotope, a multi-pass gas cell pressure control system with high precision and stability was developed in this paper. In terms of hardware, the pressure sensor was connected to the front and back end of the multi-pass gas cell to measure the inside pressure of multi-pass gas cell. The main controller regulated the proportional valves that were at the front and back end of the multi-pass gas cell via PWM signal, so as to realize the closed loop of pressure control. In terms of software, Ziegier-Nichols engineering setting method was adopted to determine three parameters P, I and D. The results show that the control accuracy is ±0.04 Torr (1 Torr=133.322 Pa) when the pressure of the multi-pass gas cell is 60 Torr. In experiment, the developed pressure control system of multi-pass cell was used to measure the absorption spectra of 13CO2 and 12CO2 gas molecules at 4.3 μm. With the increase of gas pressure from 0.026-0.066 atm(1 atm= 101 325 Pa), the peaks of the absorption spectra of 13CO2 and 12CO2 gas molecular increased with the increase of pressure, the width of the absorption spectra also increased with the increase of pressure. Meanwhile, an infrared gas measuring system was used to measure the CO2 isotope abundance during two hours. The average isotope abundance of CO2 is -9.081‰, and the fluctuation of measured values is between -8.351‰ and -9.736‰, with the maximum deviation of 0.73‰. It can be proved that the system provides reliable guarantee for high performance detection of infrared CO2 gas isotope.

    Tools

    Get Citation

    Copy Citation Text

    Huixiang Xu, Guoli Kong. Development of pressure control system for laser infrared multipass cell using Ziegler-Nichols-PID algorithm[J]. Infrared and Laser Engineering, 2020, 49(9): 20190551

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Optical design

    Received: Dec. 3, 2019

    Accepted: --

    Published Online: Jan. 4, 2021

    The Author Email: Xu Huixiang (xuhx80@126.com)

    DOI:10.3788/IRLA20190551

    Topics