Infrared and Laser Engineering, Volume. 34, Issue 6, 664(2005)

Novel method for maximum range measure of pulse laser range finder.

[in Chinese]1、*, [in Chinese]2, [in Chinese]3, [in Chinese]1, and [in Chinese]1
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • 3[in Chinese]
  • show less

    Maximum range is one of the major parameters of pulse laser range finder, Several common measurement methods are analyzed. A novel method combining outdoor light extinction ratio with indoor time sequence gain coefficient ratio is proposed, For two pulse laser range finders, outdoor light extinction ratio, indoor time sequence coefficient and maximum range are measured and compared. The results and error analysis are given. The results prove that the maximum range of the pulse laser range finder whose operating wavelength is 1.06μm and 1.54μm could be measured accurately, and it is hardly effected by weather condition and target properties, nor is effected by time sequence gain circuit. The method has high accuracy, repeatability and serviceability . By this method, other major parameters of the pulse laser range finder such as ranging accuracy, gating range, gating accuracy and range resolution can also be measured.

    Tools

    Get Citation

    Copy Citation Text

    [in Chinese], [in Chinese], [in Chinese], [in Chinese], [in Chinese]. Novel method for maximum range measure of pulse laser range finder.[J]. Infrared and Laser Engineering, 2005, 34(6): 664

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category:

    Received: Mar. 13, 2005

    Accepted: May. 14, 2005

    Published Online: May. 31, 2006

    The Author Email:

    DOI:

    Topics