Spectroscopy and Spectral Analysis, Volume. 30, Issue 12, 3199(2010)
A New Method of Characteristic Wavelength Sub-Range Selection of Near Infrared Spectroscopy
To improve and simplify the prediction model of carotenoid content of cucumber leaves, genetic algorithm (GA) combined with Metropolis acceptance criterion of simulated annealing algorithm (SAA) as well as interval partial least square (iPLS) were proposed and used to establish the calibration models of carotenoid content against cucumber leaves spectra. The cucumber leaves spectra data were divided into 40 intervals, among which 7 subsets, i.e. No.3, 4, 14, 18, 21, 32 and 33, were selected by SAA-GA-iPLS. The comparison was made between SAA-GA-iPLS and traditional genetic algorithm interval partial least square (GA-iPLS), and the result of this study shows that SAA-GA-iPLS was better than traditional genetic algorithm interval partial least square (GA-iPLS).
Get Citation
Copy Citation Text
SHI Ji-yong, ZOU Xiao-bo, ZHAO Jie-wen, YIN Xiao-ping, CHEN Zheng-wei. A New Method of Characteristic Wavelength Sub-Range Selection of Near Infrared Spectroscopy[J]. Spectroscopy and Spectral Analysis, 2010, 30(12): 3199
Received: Mar. 10, 2010
Accepted: --
Published Online: Jan. 26, 2011
The Author Email: Ji-yong SHI (stoneboy_2007@sohu.com)
CSTR:32186.14.