Laser & Optoelectronics Progress, Volume. 54, Issue 10, 100201(2017)

Temperature Measurement Technology Based on Double Line of Atomic Emission Spectra

Hu Xiaotao*, Hao Xiaojian, and Duan Xianggang
Author Affiliations
  • [in Chinese]
  • show less

    Based on the temperature measurement principles of double line of atomic emission spectrum, the photoelectric pyrometer based on silicon photomultiplier is proposed, and the structure and temperature measurement principle of the photoelectric pyrometer are introduced. Al I 690.6 nm and Al I 708.5 nm are selected from the atomic spectra database as the temperature measurement element spectral lines. The temperatures of aluminum burnt in pure oxygen are obtained by photoelectric thermometer and compared with temperatures measured by the thermocouple. The results show that the average relative error of temperatures measured by the two methods is 1.5%, which proves the feasibility of the proposed method.

    Tools

    Get Citation

    Copy Citation Text

    Hu Xiaotao, Hao Xiaojian, Duan Xianggang. Temperature Measurement Technology Based on Double Line of Atomic Emission Spectra[J]. Laser & Optoelectronics Progress, 2017, 54(10): 100201

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Atomic and Molecular Physics

    Received: May. 15, 2017

    Accepted: --

    Published Online: Oct. 9, 2017

    The Author Email: Xiaotao Hu (635499244@qq.com)

    DOI:10.3788/lop54.100201