    In this measurement of the nonlinear refraction index of 4mm thick Nd∶YVO_4 crystal, the single-beam Z scan method is employed and the experimental data is processed according to the Z scan theory of thin sample. As a result, the refraction index, which tallies with the one resulting from other different measure method, is obtained in this measurement. So the rationality and the validity of this simple measurement and data processing method are proved.