Acta Photonica Sinica, Volume. 42, Issue 8, 908(2013)
Research on Feasibility of Rapid Determination of the Moisture Content in ABC Dry Chemical Using Near Infrared Spectroscopy
Usual analytical methods are complex and require rigorous experimental condition. In order to meet the demand of fire product supervisory department in rapidly detecting the quality of dry chemical, a rapid and nondestructive method was proposed to determine the moisture content in ABC dry chemical using near infrared spectroscopy of fiber diffuse reflection. The calibration models were established for determination of moisture content of ABC dry chemical by partial least squares and 47 ABC dry chemical sample spectra. Spectral data preprocessing and Spectral region selection were discussed. Correlation Coefficient of Calibration Set of the model was 0.976, root mean square of error cross validation was 0.037 1, correlation coefficient of prediction set was 0.952, and root mean square error of prediction was 0.021 6 in the predicted rang of 0.075%~0.334% for moisture content of ABC dry chemical. Using the Chisquare test method, repeatability standard deviation measurements all belonged to the same overall at a 95% confidence level. All the relative standard deviations were less than 7.0%. The near infrared spectroscopy method is used to test the moisture content of ABC dry chemical is feasible.
Get Citation
Copy Citation Text
XUE Gang, SONG Wenqi. Research on Feasibility of Rapid Determination of the Moisture Content in ABC Dry Chemical Using Near Infrared Spectroscopy[J]. Acta Photonica Sinica, 2013, 42(8): 908
Received: Feb. 5, 2013
Accepted: --
Published Online: Sep. 25, 2013
The Author Email: Gang XUE (xuegang@tfri.com.cn)