Laser & Optoelectronics Progress, Volume. 47, Issue 3, 30901(2010)
Comparison of Commonly Used Numerical Reconstruction Algorithms in Digital Holographic Microscopy
Based on therotical analysis and experimental demonstration,three commonly used reconstruction algorithms in digital holographic microscopy,Fresnel transform algorithm,angular spectrum algorithm,and convolution algorithm,are investigated. It shows that the lensless Fourier transform digital hologram can be reconstructed at any distance by Fresnel transform algorithm. For convolution algorithm,the whole reconstructed image with high resolution can be acquired in an optimal reconstruction range or a small area around it. When the reconstruction distance is slightly smaller or larger than the optimal one,a high quality image can also be obtained by using angular spectrum algorithm. Angular spectrum algorithm is better than convolution algorithm as a whole. The Fresnel transform algorithm is time-efficient and simpler than the other two.
Get Citation
Copy Citation Text
Wang Guangjun, Wang Dayong, Wang Huaying. Comparison of Commonly Used Numerical Reconstruction Algorithms in Digital Holographic Microscopy[J]. Laser & Optoelectronics Progress, 2010, 47(3): 30901
Category: Holography
Received: May. 15, 2009
Accepted: --
Published Online: Mar. 1, 2010
The Author Email: Guangjun Wang (wangguangjun88@yahoo.com.cn)