Acta Optica Sinica, Volume. 30, Issue 7, 2017(2010)

Temperature Effect on Imaging Performance of Three-Line CCD Satellite Camera and Temperature Indicators Affirmed

Gong Dun1,2、*, Wang Hong1, and Tian Tieyin1
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less

    The surface distortion and tube length changes of three-line CCD camera at different temperatures were analyzed with finite element model. the Zernike coefficients from finite element model were put into optical-design software CODE V to calculate the decline of modulation transfer function (MTF),and the 2 ℃ temperature indicators were made by optical parameters. Thermal optical experiment was done for a variety of temperature levels on the three-line CCD camera,and the measured static transfer function of the laboratory are at or close to target 0.2. The MTF of experiment was measured and compared with the result of theoretical analysis to affirm the temperature indicators and temperature control means were reasonable.

    Tools

    Get Citation

    Copy Citation Text

    Gong Dun, Wang Hong, Tian Tieyin. Temperature Effect on Imaging Performance of Three-Line CCD Satellite Camera and Temperature Indicators Affirmed[J]. Acta Optica Sinica, 2010, 30(7): 2017

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Instrumentation, Measurement and Metrology

    Received: Sep. 3, 2009

    Accepted: --

    Published Online: Jul. 13, 2010

    The Author Email: Dun Gong (gongdun@sina.com)

    DOI:10.3788/aos20103007.2017

    Topics