    To meet the design and usage requirements of the precision light beam scanner, the thermoelastic distortion of prism is detailedly analyzed by the thermal-structure coupling method, the influence of which, on the surface deformations of prism, is conclusively proved far greater than that of only the gravity load without temperature fluctuation. With the temperature fluctuation from 20 to 20.5 Celsius degrees, the strains as well as the stresses appropriately eightfold increase, which right accords with the actual results measured by Zygo Mark interferometer with the error of not over 10%. Therefore some strict temperature-controlled measures are necessary for the scanner.

    Tools

    Get Citation

    Copy Citation Text

    Anhu Li, Jianfeng Sun, Liren Liu. Research on wavefront error of prism induced by thermoelastic distortion[J]. Chinese Optics Letters, 2006, 4(6): 323

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Received: Nov. 4, 2005

    Accepted: --

    Published Online: Jun. 12, 2006

    The Author Email: Anhu Li (yfliah@yahoo.com.cn)