Acta Optica Sinica, Volume. 29, Issue 12, 3282(2009)

A Study on Miniature Interferometer Strain Sensor Based on EFPI

Li Kun*, Wen Hongqiao, and Li Hui
Author Affiliations
  • [in Chinese]
  • show less

    A miniature extrinsic Fabry-Perot (F-P) interferometer (EFPI) sensor is fabricated by using simple etching and fusing method. The cavity is formed by wet chemical etching of multi-mode fiber (MMF) in hydrofluoric acid based solutions,then it is fused to the end of a single-mode fiber (SMF) to form a extrinsic F-P structure. Experiment results show that this kind of EFPI sensor has a high sensitivity to strain,but a low sensitivity to temperature. The strain sensitivity is about 0.00095 nm /μ ε. This kind of fiber sensor has many advantages,such as easy fabrication,high-repetition and mass-production,which offers great potential for sensing applications and especially for strain measurements in health monitoring of civil engineering structure.

    Tools

    Get Citation

    Copy Citation Text

    Li Kun, Wen Hongqiao, Li Hui. A Study on Miniature Interferometer Strain Sensor Based on EFPI[J]. Acta Optica Sinica, 2009, 29(12): 3282

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Fiber Optics and Optical Communications

    Received: Nov. 20, 2008

    Accepted: --

    Published Online: Dec. 23, 2009

    The Author Email: Kun Li (likunwz126@126.com)

    DOI:10.3788/aos20092912.3282

    Topics