Spectroscopy and Spectral Analysis, Volume. 38, Issue 6, 1987(2018)

A New Diagnostic Technique for Gas Target Thickness Based on the Doppler Shift Spectroscopy on Neutral Beam Injector

WANG Yan1,2, LIU Zhi-min1,2, YAN Jing-yang1,2, LIANG Li-zhen1, WEI Jiang-long1, and HU Chun-dong1,2
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less

    Neutral beam injection (NBI) is one of the most effective means of plasma heating and current driving. There are three basic processes in neutral beam injector: generation of ion beam,neutralization of ion beam and transmission of neutral beam, among which neutralization of ion beam is the key link. The gas target thickness in neutralizer directly affects the neutralization process, and further affects neutral beam transmission efficiency.A new diagnostic technique for the determination of gas target thickness, based on the Doppler shift effect, is presented and applied to neutral beam injector operating on Experimental Advanced Superconducting Tokamak (EAST) NBI testbed. The basis of the method is the process of beam component evolution with gas target thickness.The gas target thickness is estimated by the value of Dalpha spectral line intensity. The method is applied to the EAST NBI of Institute of Plasma physics, Chinese Academy of Sciences (ASIPP). Gas target thickness in the range of 0.16~0.22×1016 cm-2 are measured close to the exit of neutralizer,and gas target thickness measured with this novel technique correlate very well with the extracted beam current. According to the law of conservation of mass, a rough calculation of gas target thickness is basically consistent with the calculation of the novel technique, which verifies its correctness. Experimental results show that spectrum method based on the Doppler shift effect can be applied to estimate neutralizer gas target thickness.

    Tools

    Get Citation

    Copy Citation Text

    WANG Yan, LIU Zhi-min, YAN Jing-yang, LIANG Li-zhen, WEI Jiang-long, HU Chun-dong. A New Diagnostic Technique for Gas Target Thickness Based on the Doppler Shift Spectroscopy on Neutral Beam Injector[J]. Spectroscopy and Spectral Analysis, 2018, 38(6): 1987

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Received: May. 4, 2017

    Accepted: --

    Published Online: Jun. 29, 2018

    The Author Email:

    DOI:10.3964/j.issn.1000-0593(2018)06-1987-06

    Topics