High Power Laser and Particle Beams, Volume. 31, Issue 12, 124001(2019)
Simulation analysis and test of periodic focusing system with opening magnetic ring
The magnetic ring at the wave port position of the TWT periodic permanent magnet focusing system usually adopts single open magnetic ring. Two different double-open magnetic rings were proposed because of adding waveguide impedance tuning branch at the wave port position. The magnetic field near the central axis of the double-open magnetic ring was analyzed by using the 3D electromagnetic simulation software Opera-3D, and the design method of the periodic magnetic focusing system of double-open magnetic ring was put forward. In order to verify the feasibility of periodic permanent magnet focusing system with double-open magnetic rings, an electronic optical system of E-band folded waveguide TWT was designed and tested. In the traveling wave tube test, the emission current of the electron gun was 83 mA, and the electron beam flow rate of the periodic magnetic focusing system with double-open magnetic rings was 99%.
Get Citation
Copy Citation Text
Zugen Guo, Zhixin Yang, Rujing Ji, Ping Han, Ruifeng Zhang, Qi Wang, Zhanliang Wang, Yubin Gong, Huarong Gong. Simulation analysis and test of periodic focusing system with opening magnetic ring[J]. High Power Laser and Particle Beams, 2019, 31(12): 124001
Received: Jun. 11, 2019
Accepted: --
Published Online: Mar. 30, 2020
The Author Email: Gong Huarong (hrgong@uestc.edu.cn)