Acta Photonica Sinica, Volume. 43, Issue 4, 430001(2014)

Theoretical Analysis and Research about High Image Quality Offner Imaging Spectrometer

HAN Shan*, HUANG Yuan-shen, LI Bai-cheng, ZHANG Da-wei, NI Zheng-ji, and ZHUANG Song-lin
Author Affiliations
  • [in Chinese]
  • show less

    The Offner imaging spectrometer was built on the basis of the double mirror system, and its initial structure was obtained through solving optical path function. Through simulating and optimizing the initial structure using professional optical design software (Code V), the high image quality of spectrometer was obtained. Its root mean square spot diameter decreased obviously, and modulation transfer function curves in meridianal and sagittial had good imaging results. The study can eliminate overly complex aberration derivation process, and obtain high image quality Offner spectrometer structure in a wide spectrum (400~1 300 nm). It can provide a theoretical basis for the construction of the spectrometer.

    Tools

    Get Citation

    Copy Citation Text

    HAN Shan, HUANG Yuan-shen, LI Bai-cheng, ZHANG Da-wei, NI Zheng-ji, ZHUANG Song-lin. Theoretical Analysis and Research about High Image Quality Offner Imaging Spectrometer[J]. Acta Photonica Sinica, 2014, 43(4): 430001

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Received: Jul. 22, 2013

    Accepted: --

    Published Online: May. 4, 2014

    The Author Email: Shan HAN (hanshangf@126.com)

    DOI:10.3788/gzxb20144304.0430001

    Topics