Acta Optica Sinica, Volume. 25, Issue 10, 1357(2005)

Research for Visual Range of Low Light Level Imaging System Under the Laser Aids

[in Chinese]*, [in Chinese], and [in Chinese]

The maximal visual range of low light level (LLL) imaging apparatus is a basic guideline in system's design. Based on the early work, the visual range equation of LLL imaging system has been summarized. The laser aids system is used in order to improve its watching ability in bad weather. If so, there would be changed in the equation of visual range, especially the spectral matching factor. What's more, the illumination, contrast, reflectivity and so on would be changed. The changes about these factors after the adding of the laser are discussed, which can help choosing the lasers. The visual range of the super second generation image intensifiers under the laser aids is estimated, which proved the laser (λ=850 nm) is reasonable.

Tools

Get Citation

Copy Citation Text

[in Chinese], [in Chinese], [in Chinese]. Research for Visual Range of Low Light Level Imaging System Under the Laser Aids[J]. Acta Optica Sinica, 2005, 25(10): 1357

Download Citation

EndNote(RIS)BibTexPlain Text
Save article for my favorites
Paper Information

Category: Lasers and Laser Optics

Received: Sep. 16, 2004

Accepted: --

Published Online: May. 23, 2006

The Author Email:

DOI:

Topics