Optical Communication Technology, Volume. 47, Issue 6, 15(2021)

Application of optical fiber diagnosis in large dynamic OTDR extra-high voltage direct-current control system

RUAN Jun... LI Junyu, SUN Hao and ZHU Zhijun |Show fewer author(s)
Author Affiliations
  • [in Chinese]
  • show less

    Increasing the transmited pulse width of optical time domain reflectometer(OTDR) may lead to saturation effect of ava-lanche photodiode(APD) in the detection circuit of OTDR, and makes the measured curve flat roof effect, which will submerge the short-range event results. To solve this problem, this paper proposes a multi-pulse width combined measurement method, the measurement results are software spliced to achieve a longer measurement distance under the condition of the hardware configuration unchanged, and the near-end events will not be submerged by the flat roof due to the saturated flat roof effect, the dynamic range of OTDR measurement is improved.

    Tools

    Get Citation

    Copy Citation Text

    RUAN Jun, LI Junyu, SUN Hao, ZHU Zhijun. Application of optical fiber diagnosis in large dynamic OTDR extra-high voltage direct-current control system[J]. Optical Communication Technology, 2021, 47(6): 15

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category:

    Received: Oct. 23, 2020

    Accepted: --

    Published Online: Sep. 2, 2021

    The Author Email:

    DOI:10.13921/j.cnki.issn1002-5561.2021.06.004