Laser & Optoelectronics Progress, Volume. 58, Issue 19, 1929002(2021)

Microwave Instantaneous Frequency Measurement Based on Single Lightpath Polarization Multiplexing

Lanfeng Huang1, Yongjun Li1、*, Shanghong Zhao1, Tao Lin1, Taijiang Zhang2, and Haiyan Zhao1
Author Affiliations
  • 1Information and Navigation College, Air Force Engineering University, Xi'an , Shaanxi 710077, China
  • 2Unit 75835 of the People's Liberation Army of China, Guangzhou , Guangdong 510500, China
  • show less

    A microwave instantaneous frequency measurement scheme based on single lightpath polarization multiplexing technology was proposed. This technique requires only a dual-polarization dual-drive Mach-Zehnder modulator to provide the pump light and probe light needed for stimulated Brillouin scattering. Compared with the previous dual-channel Brillouin scattering technique, the proposed technique offers the advantages of a simple structure, compression system volume, stable and controllable pump light and detection light interference, and improved system stability. The unknown microwave signal was modulated using carrier suppression double sideband modulation as the pump light, and the swept-frequency detection signal was phase modulated as the scanning detection light. Moreover, the conversion from phase modulation to intensity modulation was realized using the stimulated Brillouin scattering effect. The microwave signal instantaneous frequency was measured by establishing a mapping relationship between the scanning frequency and the output optical power. Theoretical and simulation models were established to study the influence of the pump light wavelength jitter, DC bias point drift, phase drift of electric phase shifter, and polarization state shift of pump light and probe light on frequency measurement accuracy. Research results show that the proposed scheme can measure the frequency of microwave signals above 30 GHz. Furthermore, the maximum absolute measurement error does not exceed 30 MHz, while the relative measurement error is less than 2%. The frequency measurement range can be increased by increasing the scanning range of the frequency sweep detection signal and the modulation frequency range of the modulator. The proposed scheme has the advantages of a compact structure, stable performance, and simple operation and has a wide application prospect in low-cost and wide-spectrum radar detection.

    Tools

    Get Citation

    Copy Citation Text

    Lanfeng Huang, Yongjun Li, Shanghong Zhao, Tao Lin, Taijiang Zhang, Haiyan Zhao. Microwave Instantaneous Frequency Measurement Based on Single Lightpath Polarization Multiplexing[J]. Laser & Optoelectronics Progress, 2021, 58(19): 1929002

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Scattering

    Received: Feb. 1, 2021

    Accepted: Mar. 2, 2021

    Published Online: Oct. 14, 2021

    The Author Email: Li Yongjun (tz_228@163.com)

    DOI:10.3788/LOP202158.1929002

    Topics